Nuclear Data Sensitivity of Minor Actinides on Accelerator driven Burner System
doi: 10.11804/NuclPhysRev.21.01.070
- Received Date: 1900-01-01
- Rev Recd Date: 1900-01-01
- Publish Date: 2004-03-20
-
Key words:
- minor actinide /
- evaluation library /
- accelerator driven system /
- Keff /
- reaction rate
Abstract: In order to investigate the effect of minior actinide data on integral parameter, the acceleratordriven minior actinide benchmark system was selected in this work. The library based on ENDF/BVI.2 was used for the reference calculation. The sensitivities were examined by exchanging the minior actinides of CENDL3.0 and JENDL3.2 one after another. The Keff values and reaction rates were calculated. According to the comparisons, the difference in Keff from the refrence is more than 3‰, and the fission reaction rate of 242Am is about 15% lower than those of reference results. The elastic scattering reaction rate of 238Pu of CENDL3.0 is about 10% larger than those of ENDF/BVI.
Citation: | LIU Ping, ZHAO Zhi-xiang. Nuclear Data Sensitivity of Minor Actinides on Accelerator driven Burner System[J]. Nuclear Physics Review, 2004, 21(1): 70-72. doi: 10.11804/NuclPhysRev.21.01.070 |