Guo HongSheng, He XiJun, Peng TaiPing. Measurements of Parameters on Large Area PIN Detectors[J]. Nuclear Physics Review, 2005, 22(3): 272-275. doi: 10.11804/NuclPhysRev.22.03.272
Citation: Guo HongSheng, He XiJun, Peng TaiPing. Measurements of Parameters on Large Area PIN Detectors[J]. Nuclear Physics Review, 2005, 22(3): 272-275. doi: 10.11804/NuclPhysRev.22.03.272

Measurements of Parameters on Large Area PIN Detectors

doi: 10.11804/NuclPhysRev.22.03.272
  • Received Date: 1900-01-01
  • Rev Recd Date: 1900-01-01
  • Publish Date: 2005-09-20
  • Ф60 mm silicon PIN detector is a large area and high sensitive one which has been developed in near years. Using the type CГC-67 γ accelerator, the parameters of PIN detectors such as time response, linear current and relative sensitivity are measured. The experiment results are compared with the theory calculation. The PIN detector can reach high γefficiency of up to 10^-14-10^-16 C·cm2, the rise time is about 10 ns and the FWHM of the time pulse is about 35 ns. The γ efficiency of the PIN detector may provide the sensitive range between 10^-14-10^-16 C·cm^2 that scintillator + photo tubes detecting system and scintillator + photomul tiplier tubes detecting system is not developed.
  • 加载中
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Article Metrics

Article views(2124) PDF downloads(710) Cited by()

Proportional views

Measurements of Parameters on Large Area PIN Detectors

doi: 10.11804/NuclPhysRev.22.03.272

Abstract: Ф60 mm silicon PIN detector is a large area and high sensitive one which has been developed in near years. Using the type CГC-67 γ accelerator, the parameters of PIN detectors such as time response, linear current and relative sensitivity are measured. The experiment results are compared with the theory calculation. The PIN detector can reach high γefficiency of up to 10^-14-10^-16 C·cm2, the rise time is about 10 ns and the FWHM of the time pulse is about 35 ns. The γ efficiency of the PIN detector may provide the sensitive range between 10^-14-10^-16 C·cm^2 that scintillator + photo tubes detecting system and scintillator + photomul tiplier tubes detecting system is not developed.

Guo HongSheng, He XiJun, Peng TaiPing. Measurements of Parameters on Large Area PIN Detectors[J]. Nuclear Physics Review, 2005, 22(3): 272-275. doi: 10.11804/NuclPhysRev.22.03.272
Citation: Guo HongSheng, He XiJun, Peng TaiPing. Measurements of Parameters on Large Area PIN Detectors[J]. Nuclear Physics Review, 2005, 22(3): 272-275. doi: 10.11804/NuclPhysRev.22.03.272

Catalog

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return