WU Ai-dong, CHEN Yi-xue, WU Yi-can, LIU Lei. Study on Dosimetry Characteristics of P-type Semiconductor Detector in Radiotherapy[J]. Nuclear Physics Review, 2006, 23(2): 224-228. doi: 10.11804/NuclPhysRev.23.02.224
Citation: WU Ai-dong, CHEN Yi-xue, WU Yi-can, LIU Lei. Study on Dosimetry Characteristics of P-type Semiconductor Detector in Radiotherapy[J]. Nuclear Physics Review, 2006, 23(2): 224-228. doi: 10.11804/NuclPhysRev.23.02.224

Study on Dosimetry Characteristics of P-type Semiconductor Detector in Radiotherapy

doi: 10.11804/NuclPhysRev.23.02.224
  • Received Date: 1900-01-01
  • Rev Recd Date: 1900-01-01
  • Publish Date: 2006-06-20
  • The measurement accuracy of electron beam by using semiconductor detector is easily affected by beam energy, dose rate, beam incidence direction, environment temperature etc. Furthermore, the presence of the detectors on the patient surface perturbs the distribution of the radiation field. In the paper, the dose characteristics of semiconductor detector are quantitatively discussed. The perturbation of the symmetrical radiation field is investigated based on the measured results of P-type electron beam detector under different clinical conditions.
  • 加载中
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Article Metrics

Article views(2010) PDF downloads(786) Cited by()

Proportional views

Study on Dosimetry Characteristics of P-type Semiconductor Detector in Radiotherapy

doi: 10.11804/NuclPhysRev.23.02.224

Abstract: The measurement accuracy of electron beam by using semiconductor detector is easily affected by beam energy, dose rate, beam incidence direction, environment temperature etc. Furthermore, the presence of the detectors on the patient surface perturbs the distribution of the radiation field. In the paper, the dose characteristics of semiconductor detector are quantitatively discussed. The perturbation of the symmetrical radiation field is investigated based on the measured results of P-type electron beam detector under different clinical conditions.

WU Ai-dong, CHEN Yi-xue, WU Yi-can, LIU Lei. Study on Dosimetry Characteristics of P-type Semiconductor Detector in Radiotherapy[J]. Nuclear Physics Review, 2006, 23(2): 224-228. doi: 10.11804/NuclPhysRev.23.02.224
Citation: WU Ai-dong, CHEN Yi-xue, WU Yi-can, LIU Lei. Study on Dosimetry Characteristics of P-type Semiconductor Detector in Radiotherapy[J]. Nuclear Physics Review, 2006, 23(2): 224-228. doi: 10.11804/NuclPhysRev.23.02.224

Catalog

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return