ZHAO Pan, CHEN Yi-xue, LIN Hui, ZHENG Shan-liang, WU Yi-can. Effect of Different Voxel-uniting Methods on the Dose Calculation of MCNP/MCNPX[J]. Nuclear Physics Review, 2006, 23(2): 258-262. doi: 10.11804/NuclPhysRev.23.02.258
Citation: ZHAO Pan, CHEN Yi-xue, LIN Hui, ZHENG Shan-liang, WU Yi-can. Effect of Different Voxel-uniting Methods on the Dose Calculation of MCNP/MCNPX[J]. Nuclear Physics Review, 2006, 23(2): 258-262. doi: 10.11804/NuclPhysRev.23.02.258

Effect of Different Voxel-uniting Methods on the Dose Calculation of MCNP/MCNPX

doi: 10.11804/NuclPhysRev.23.02.258
  • Received Date: 1900-01-01
  • Rev Recd Date: 1900-01-01
  • Publish Date: 2006-06-20
  • The key problem for the application of the Monte Carlo particle transport code MCNP/MCNPX in radiotherapy is the creation of complex geometrical model. To handle this problem, a software has been developed to automatically create MCNP/MCNPX geometrical model based on the CT images, and three geometric cell treatment schemes were proposed and implemented in this software. In this work, three MCNP models are created, and calculations are performed to investigate the effect of those cell treatment schemes and repeated structure technique on the calculation results.
  • 加载中
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Article Metrics

Article views(2349) PDF downloads(902) Cited by()

Proportional views

Effect of Different Voxel-uniting Methods on the Dose Calculation of MCNP/MCNPX

doi: 10.11804/NuclPhysRev.23.02.258

Abstract: The key problem for the application of the Monte Carlo particle transport code MCNP/MCNPX in radiotherapy is the creation of complex geometrical model. To handle this problem, a software has been developed to automatically create MCNP/MCNPX geometrical model based on the CT images, and three geometric cell treatment schemes were proposed and implemented in this software. In this work, three MCNP models are created, and calculations are performed to investigate the effect of those cell treatment schemes and repeated structure technique on the calculation results.

ZHAO Pan, CHEN Yi-xue, LIN Hui, ZHENG Shan-liang, WU Yi-can. Effect of Different Voxel-uniting Methods on the Dose Calculation of MCNP/MCNPX[J]. Nuclear Physics Review, 2006, 23(2): 258-262. doi: 10.11804/NuclPhysRev.23.02.258
Citation: ZHAO Pan, CHEN Yi-xue, LIN Hui, ZHENG Shan-liang, WU Yi-can. Effect of Different Voxel-uniting Methods on the Dose Calculation of MCNP/MCNPX[J]. Nuclear Physics Review, 2006, 23(2): 258-262. doi: 10.11804/NuclPhysRev.23.02.258

Catalog

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return