A Two Dimensional Position Sensitive CsI(Tl) Scintillation Detector
doi: 10.11804/NuclPhysRev.25.01.052
- Received Date: 1900-01-01
- Rev Recd Date: 1900-01-01
- Publish Date: 2008-03-20
-
Key words:
- GEANT4 /
- CsI(Tl) scintillation detector /
- position resolution /
- reflection factor
Abstract: A two dimensional position sensitive CsI(Tl) scintillation detector readout with PSPMT was introduced. The performance of detector was simulated by using Monte Carlo code GEANT4. The position spectrum of RIB 17N and the detector’s position resolution were obtained, and the simulation results accorded with the experimental ones. The main factors, which can affect performance of the detector, and some planned detector improvements were presented.
Citation: | HU Qiang, LI Jia-xing. A Two Dimensional Position Sensitive CsI(Tl) Scintillation Detector[J]. Nuclear Physics Review, 2008, 25(1): 52-55. doi: 10.11804/NuclPhysRev.25.01.052 |