Advanced Search

WANG Song-lin, KONG Xiang-zhong, DENG Yong-jun, TUO Fei, WANG Qi, WEI Jin-feng, LI Yong-ming. Neutron Spectrum Measurement with Activation Method in Sample Place of Online Neutron Activation Analysis System[J]. Nuclear Physics Review, 2009, 26(1): 27-32. doi: 10.11804/NuclPhysRev.26.01.027
Citation: WANG Song-lin, KONG Xiang-zhong, DENG Yong-jun, TUO Fei, WANG Qi, WEI Jin-feng, LI Yong-ming. Neutron Spectrum Measurement with Activation Method in Sample Place of Online Neutron Activation Analysis System[J]. Nuclear Physics Review, 2009, 26(1): 27-32. doi: 10.11804/NuclPhysRev.26.01.027

Neutron Spectrum Measurement with Activation Method in Sample Place of Online Neutron Activation Analysis System

doi: 10.11804/NuclPhysRev.26.01.027
More Information
  • Corresponding author: WANG Song-lin
  • Received Date: 1900-01-01
  • Rev Recd Date: 1900-01-01
  • Publish Date: 2009-03-20
  • The neutron spectrum in sample place of online neutron activation analysis system was measured with multiple foil activation technique. According to the neutron fluence level of measuring request, 5 kinds of nonfission nuclear material foils were selected, of which 4 were sensitive to thermal energy region and intermediate energy region, and 1 was sensitive to fast energy region. By measuring the foil activity, the neutron spectrum that was needed to measured was unfolded with the iterative methods SANDII and MSIT. Meanwhile, the process of producing and modifying group cross section were analysed amply. The main factors which have influence on the accuracy of the solution were studied. The discussion for solution was done simply, and the uncertainty of solution was analysed by using the Monte Carlo method.
  • 加载中
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Article Metrics

Article views(2042) PDF downloads(708) Cited by()

Proportional views

Neutron Spectrum Measurement with Activation Method in Sample Place of Online Neutron Activation Analysis System

doi: 10.11804/NuclPhysRev.26.01.027
    Corresponding author: WANG Song-lin

Abstract: The neutron spectrum in sample place of online neutron activation analysis system was measured with multiple foil activation technique. According to the neutron fluence level of measuring request, 5 kinds of nonfission nuclear material foils were selected, of which 4 were sensitive to thermal energy region and intermediate energy region, and 1 was sensitive to fast energy region. By measuring the foil activity, the neutron spectrum that was needed to measured was unfolded with the iterative methods SANDII and MSIT. Meanwhile, the process of producing and modifying group cross section were analysed amply. The main factors which have influence on the accuracy of the solution were studied. The discussion for solution was done simply, and the uncertainty of solution was analysed by using the Monte Carlo method.

WANG Song-lin, KONG Xiang-zhong, DENG Yong-jun, TUO Fei, WANG Qi, WEI Jin-feng, LI Yong-ming. Neutron Spectrum Measurement with Activation Method in Sample Place of Online Neutron Activation Analysis System[J]. Nuclear Physics Review, 2009, 26(1): 27-32. doi: 10.11804/NuclPhysRev.26.01.027
Citation: WANG Song-lin, KONG Xiang-zhong, DENG Yong-jun, TUO Fei, WANG Qi, WEI Jin-feng, LI Yong-ming. Neutron Spectrum Measurement with Activation Method in Sample Place of Online Neutron Activation Analysis System[J]. Nuclear Physics Review, 2009, 26(1): 27-32. doi: 10.11804/NuclPhysRev.26.01.027

Catalog

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return