Advanced Search

MA Shuang, LI Wen-jian, #, WANG Ju-fang, ZHOU Li-bin, YU Li-xia, DONG Xi-cun, . Mutagenic Effects of Biocontrol BacteriumBJ1 Irradiated by Different LET of 12C6+ Ion Beam[J]. Nuclear Physics Review, 2009, 26(2): 168-171. doi: 10.11804/NuclPhysRev.26.02.168
Citation: MA Shuang, LI Wen-jian, #, WANG Ju-fang, ZHOU Li-bin, YU Li-xia, DONG Xi-cun, . Mutagenic Effects of Biocontrol BacteriumBJ1 Irradiated by Different LET of 12C6+ Ion Beam[J]. Nuclear Physics Review, 2009, 26(2): 168-171. doi: 10.11804/NuclPhysRev.26.02.168

Mutagenic Effects of Biocontrol BacteriumBJ1 Irradiated by Different LET of 12C6+ Ion Beam

doi: 10.11804/NuclPhysRev.26.02.168
  • Received Date: 1900-01-01
  • Rev Recd Date: 1900-01-01
  • Publish Date: 2009-06-20
  • To explore the effects of different linear energy transfer(LET)of 12C6+ ion Beam irradiation on BJ1, survivals and biocontrol effects were cultured and treated with LET=40 and 60 keV/μm at the doses of 50, 100, 200, 400 and 600 Gy, respectively. The results showed more mutations and biocontrol charts and higher survivals were obtained with high LET(60 keV/μm) irradiations at lower dose, which was useful to screen good positive mutations. Based on the results above, it could be concluded that the condition of high LET(60 keV/μm) had obvious mutagenic effects than that of low LET(40 keV/μm).
  • 加载中
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Article Metrics

Article views(2005) PDF downloads(699) Cited by()

Proportional views

Mutagenic Effects of Biocontrol BacteriumBJ1 Irradiated by Different LET of 12C6+ Ion Beam

doi: 10.11804/NuclPhysRev.26.02.168

Abstract: To explore the effects of different linear energy transfer(LET)of 12C6+ ion Beam irradiation on BJ1, survivals and biocontrol effects were cultured and treated with LET=40 and 60 keV/μm at the doses of 50, 100, 200, 400 and 600 Gy, respectively. The results showed more mutations and biocontrol charts and higher survivals were obtained with high LET(60 keV/μm) irradiations at lower dose, which was useful to screen good positive mutations. Based on the results above, it could be concluded that the condition of high LET(60 keV/μm) had obvious mutagenic effects than that of low LET(40 keV/μm).

MA Shuang, LI Wen-jian, #, WANG Ju-fang, ZHOU Li-bin, YU Li-xia, DONG Xi-cun, . Mutagenic Effects of Biocontrol BacteriumBJ1 Irradiated by Different LET of 12C6+ Ion Beam[J]. Nuclear Physics Review, 2009, 26(2): 168-171. doi: 10.11804/NuclPhysRev.26.02.168
Citation: MA Shuang, LI Wen-jian, #, WANG Ju-fang, ZHOU Li-bin, YU Li-xia, DONG Xi-cun, . Mutagenic Effects of Biocontrol BacteriumBJ1 Irradiated by Different LET of 12C6+ Ion Beam[J]. Nuclear Physics Review, 2009, 26(2): 168-171. doi: 10.11804/NuclPhysRev.26.02.168

Catalog

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return