Advanced Search
Volume 26 Issue S1
May  2020
Turn off MathJax
Article Contents

LUO Wen, XU Wang, PAN Qiang-yan, XU Yi, FAN Gong-tao, et al.. A Simple Xray Spectrometer and PCbased Data Acquisition System for Newly Developed Xray Source Based on Laser Compton Scattering[J]. Nuclear Physics Review, 2009, 26(5): 115-118. doi: 10.11804/NuclPhysRev.26.S1.115
Citation: LUO Wen, XU Wang, PAN Qiang-yan, XU Yi, FAN Gong-tao, et al.. A Simple Xray Spectrometer and PCbased Data Acquisition System for Newly Developed Xray Source Based on Laser Compton Scattering[J]. Nuclear Physics Review, 2009, 26(5): 115-118. doi: 10.11804/NuclPhysRev.26.S1.115

A Simple Xray Spectrometer and PCbased Data Acquisition System for Newly Developed Xray Source Based on Laser Compton Scattering

doi: 10.11804/NuclPhysRev.26.S1.115
  • Received Date: 1900-01-01
  • Rev Recd Date: 1900-01-01
  • Publish Date: 2020-05-11
  • A simple Xray spectrometer and a PCBased Data Acquisition System(DAS) have been developed newly in Shanghai Institute of Applied Physics(SINAP), Chinese Academy of Sciences(CAS) for the measurement of the Xray source generated using laser Compton scattering. The system consists of liquid nitrogen cooled high resolution Si(Li) detector, electronics and a DAQ. The Si(Li) detector was designed and made by Center of Advanced Instruments in SINAP, CAS, it allows us to measure Xrays with the energy up to 60 keV and the energy resolution(FWHM) of 184 eV at 5.9 keV. We measured the system uncertainty was 0.2 eV and time drifting of detector was 0.05% both at 5.9 keV. The DAQ was based on ObjectOriented software LabVIEW 7.1, it has data online analysis and original data saved functions.
  • 加载中
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Article Metrics

Article views(1968) PDF downloads(543) Cited by()

Proportional views

A Simple Xray Spectrometer and PCbased Data Acquisition System for Newly Developed Xray Source Based on Laser Compton Scattering

doi: 10.11804/NuclPhysRev.26.S1.115

Abstract: A simple Xray spectrometer and a PCBased Data Acquisition System(DAS) have been developed newly in Shanghai Institute of Applied Physics(SINAP), Chinese Academy of Sciences(CAS) for the measurement of the Xray source generated using laser Compton scattering. The system consists of liquid nitrogen cooled high resolution Si(Li) detector, electronics and a DAQ. The Si(Li) detector was designed and made by Center of Advanced Instruments in SINAP, CAS, it allows us to measure Xrays with the energy up to 60 keV and the energy resolution(FWHM) of 184 eV at 5.9 keV. We measured the system uncertainty was 0.2 eV and time drifting of detector was 0.05% both at 5.9 keV. The DAQ was based on ObjectOriented software LabVIEW 7.1, it has data online analysis and original data saved functions.

LUO Wen, XU Wang, PAN Qiang-yan, XU Yi, FAN Gong-tao, et al.. A Simple Xray Spectrometer and PCbased Data Acquisition System for Newly Developed Xray Source Based on Laser Compton Scattering[J]. Nuclear Physics Review, 2009, 26(5): 115-118. doi: 10.11804/NuclPhysRev.26.S1.115
Citation: LUO Wen, XU Wang, PAN Qiang-yan, XU Yi, FAN Gong-tao, et al.. A Simple Xray Spectrometer and PCbased Data Acquisition System for Newly Developed Xray Source Based on Laser Compton Scattering[J]. Nuclear Physics Review, 2009, 26(5): 115-118. doi: 10.11804/NuclPhysRev.26.S1.115

Catalog

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return