A Beam Position Monitor System for Electron Cooler in HIRFL-CSR

doi: 10.11804/NuclPhysRev.27.01.043
  • Received Date: 1900-01-01
  • Rev Recd Date: 1900-01-01
  • Publish Date: 2010-03-20
  • The efficient electron cooling requires that the ion beam and electron beam are parallel and overlapped. In order to measure the positions of ion beam and electron beam simultaneously, a beam position monitor system is developed for the HIRFL-CSR electron cooler device, which probe consists of four capacitive cylinder linearcut poles. One can get the both beam positions from the picking up signals of four poles by using Fourier transform(FFT) method. The measurement results show that the beam position monitor system is accurate. This system is suitable for investigating the relation between electron cooling processing and the angle of ion beam and electron beam.
  • 加载中
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Article Metrics

Article views(2477) PDF downloads(718) Cited by()

Proportional views

A Beam Position Monitor System for Electron Cooler in HIRFL-CSR

doi: 10.11804/NuclPhysRev.27.01.043

Abstract: The efficient electron cooling requires that the ion beam and electron beam are parallel and overlapped. In order to measure the positions of ion beam and electron beam simultaneously, a beam position monitor system is developed for the HIRFL-CSR electron cooler device, which probe consists of four capacitive cylinder linearcut poles. One can get the both beam positions from the picking up signals of four poles by using Fourier transform(FFT) method. The measurement results show that the beam position monitor system is accurate. This system is suitable for investigating the relation between electron cooling processing and the angle of ion beam and electron beam.

LI Guo-hong, YANG Xiao-dong, #, MAO Li-jun, LI Jie, YAN Tai-lai, MA Xiao-ming. A Beam Position Monitor System for Electron Cooler in HIRFL-CSR[J]. Nuclear Physics Review, 2010, 27(1): 43-47. doi: 10.11804/NuclPhysRev.27.01.043
Citation: LI Guo-hong, YANG Xiao-dong, #, MAO Li-jun, LI Jie, YAN Tai-lai, MA Xiao-ming. A Beam Position Monitor System for Electron Cooler in HIRFL-CSR[J]. Nuclear Physics Review, 2010, 27(1): 43-47. doi: 10.11804/NuclPhysRev.27.01.043

Catalog

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return