WANG Wei, YU De-yang, #, SHE Qian-sun, XU Zhi-guo, CHEN Jing, SU Hong, CAI Xiao-hong, #. A 64 Channel Position Sensitive Current Distribution Detector with Data Acquisition System[J]. Nuclear Physics Review, 2010, 27(2): 174-177. doi: 10.11804/NuclPhysRev.27.02.174
Citation: WANG Wei, YU De-yang, #, SHE Qian-sun, XU Zhi-guo, CHEN Jing, SU Hong, CAI Xiao-hong, #. A 64 Channel Position Sensitive Current Distribution Detector with Data Acquisition System[J]. Nuclear Physics Review, 2010, 27(2): 174-177. doi: 10.11804/NuclPhysRev.27.02.174

A 64 Channel Position Sensitive Current Distribution Detector with Data Acquisition System

doi: 10.11804/NuclPhysRev.27.02.174
  • Received Date: 1900-01-01
  • Rev Recd Date: 1900-01-01
  • Publish Date: 2010-06-20
  • A 64channel position sensitive current distribution detector with 1 mm position resolution was developed, while the data acquisition system is based on the LabVIEW software. The test result obtained by using a 2 nA, 200—2000 eV electron beam deflecting by different voltages and the position spectra of 10 μA, 2000 eV electrons transmitted through a glass capillary was measured. The result indicated that the detector can be used to detect the charged particles with strong beam current through the capillary.
  • 加载中
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Article Metrics

Article views(3201) PDF downloads(739) Cited by()

Proportional views

A 64 Channel Position Sensitive Current Distribution Detector with Data Acquisition System

doi: 10.11804/NuclPhysRev.27.02.174

Abstract: A 64channel position sensitive current distribution detector with 1 mm position resolution was developed, while the data acquisition system is based on the LabVIEW software. The test result obtained by using a 2 nA, 200—2000 eV electron beam deflecting by different voltages and the position spectra of 10 μA, 2000 eV electrons transmitted through a glass capillary was measured. The result indicated that the detector can be used to detect the charged particles with strong beam current through the capillary.

WANG Wei, YU De-yang, #, SHE Qian-sun, XU Zhi-guo, CHEN Jing, SU Hong, CAI Xiao-hong, #. A 64 Channel Position Sensitive Current Distribution Detector with Data Acquisition System[J]. Nuclear Physics Review, 2010, 27(2): 174-177. doi: 10.11804/NuclPhysRev.27.02.174
Citation: WANG Wei, YU De-yang, #, SHE Qian-sun, XU Zhi-guo, CHEN Jing, SU Hong, CAI Xiao-hong, #. A 64 Channel Position Sensitive Current Distribution Detector with Data Acquisition System[J]. Nuclear Physics Review, 2010, 27(2): 174-177. doi: 10.11804/NuclPhysRev.27.02.174

Catalog

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return