Preliminary Test of MICROMEGAS Gaseous Detector

doi: 10.11804/NuclPhysRev.28.01.068
  • Received Date: 1900-01-01
  • Rev Recd Date: 1900-01-01
  • Publish Date: 2011-03-20
  • In this paper,A MICROMEGAS(MicroMeshGaseous Structure) detector with the amplification gap defined by stretching nylon fishing lines has been described . And its count plateau, gas gain and energy resolution in the condition of a 55Fe Xray source and ArCO2 (10%) mixture gases are measured as functions of mesh voltage. The count plateau approaches 280 V at the count rate of 103 Hz. The discharge rate is less than 10-4 when the gas gain is up to 104. The energy resolution is 30% (FWHM) based on -800 V mesh voltage. The position resolution is less than 120 μm at the condition of the sensitive area (50 mm×50 mm) Printed Circuit Boards (PCB) and its strip pitch of 400 μm. The results can satisfy the basic demand of MICROMEGAS detector preliminary design.
  • 加载中
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Article Metrics

Article views(2317) PDF downloads(625) Cited by()

Proportional views

Preliminary Test of MICROMEGAS Gaseous Detector

doi: 10.11804/NuclPhysRev.28.01.068

Abstract: In this paper,A MICROMEGAS(MicroMeshGaseous Structure) detector with the amplification gap defined by stretching nylon fishing lines has been described . And its count plateau, gas gain and energy resolution in the condition of a 55Fe Xray source and ArCO2 (10%) mixture gases are measured as functions of mesh voltage. The count plateau approaches 280 V at the count rate of 103 Hz. The discharge rate is less than 10-4 when the gas gain is up to 104. The energy resolution is 30% (FWHM) based on -800 V mesh voltage. The position resolution is less than 120 μm at the condition of the sensitive area (50 mm×50 mm) Printed Circuit Boards (PCB) and its strip pitch of 400 μm. The results can satisfy the basic demand of MICROMEGAS detector preliminary design.

LU Chen-gui, DUAN Li-min, #, YANG He-run, MA Peng, TANG Shu-wen, HU Rong-jiang, LI Zu-yu, . Preliminary Test of MICROMEGAS Gaseous Detector[J]. Nuclear Physics Review, 2011, 28(1): 68-70. doi: 10.11804/NuclPhysRev.28.01.068
Citation: LU Chen-gui, DUAN Li-min, #, YANG He-run, MA Peng, TANG Shu-wen, HU Rong-jiang, LI Zu-yu, . Preliminary Test of MICROMEGAS Gaseous Detector[J]. Nuclear Physics Review, 2011, 28(1): 68-70. doi: 10.11804/NuclPhysRev.28.01.068

Catalog

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return