Advanced Search

MCNP Dose Calculations in a CT Phantom for Therapeutic External Photon Beam[J]. Nuclear Physics Review, 2011, 28(2): 236-240. doi: 10.11804/NuclPhysRev.28.02.236
Citation: MCNP Dose Calculations in a CT Phantom for Therapeutic External Photon Beam[J]. Nuclear Physics Review, 2011, 28(2): 236-240. doi: 10.11804/NuclPhysRev.28.02.236

MCNP Dose Calculations in a CT Phantom for Therapeutic External Photon Beam

doi: 10.11804/NuclPhysRev.28.02.236
  • Received Date: 1900-01-01
  • Rev Recd Date: 1900-01-01
  • Publish Date: 2011-06-20
  • In this paper, we have addressed the problem of the radiation transport with the Monte Carlo Nparticle(MCNP) code. This is a generalpurpose Monte Carlo tool designed to transport neutron, photon and electron in three dimensional geometries. To examine the performance of MCNP5 code in the field of external radiotherapy, we performed the modeling of an Electron Density phantom (EDP) irradiated by photons from 60Co source. The model was used to calculate the Percent Depth Dose (PDD) at different depths in an EDP. One field size for PDD has been examined. A 60Co photons source placed at 80 cm source to surface distance (SSD). The results of calculations were compared to TPS data obtained at National Institute of Oncology of Rabat.
  • 加载中
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Article Metrics

Article views(1875) PDF downloads(535) Cited by()

Proportional views

MCNP Dose Calculations in a CT Phantom for Therapeutic External Photon Beam

doi: 10.11804/NuclPhysRev.28.02.236

Abstract: In this paper, we have addressed the problem of the radiation transport with the Monte Carlo Nparticle(MCNP) code. This is a generalpurpose Monte Carlo tool designed to transport neutron, photon and electron in three dimensional geometries. To examine the performance of MCNP5 code in the field of external radiotherapy, we performed the modeling of an Electron Density phantom (EDP) irradiated by photons from 60Co source. The model was used to calculate the Percent Depth Dose (PDD) at different depths in an EDP. One field size for PDD has been examined. A 60Co photons source placed at 80 cm source to surface distance (SSD). The results of calculations were compared to TPS data obtained at National Institute of Oncology of Rabat.

MCNP Dose Calculations in a CT Phantom for Therapeutic External Photon Beam[J]. Nuclear Physics Review, 2011, 28(2): 236-240. doi: 10.11804/NuclPhysRev.28.02.236
Citation: MCNP Dose Calculations in a CT Phantom for Therapeutic External Photon Beam[J]. Nuclear Physics Review, 2011, 28(2): 236-240. doi: 10.11804/NuclPhysRev.28.02.236

Catalog

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return