Advanced Search

TANG Shu-wen, DUAN Li-min, SUN Zhi-yu, MA Peng, LU Chen-gui, YANG He-run, ZHANG Jin-xia, HU Zheng-guo, XU Hu-shan. A Longitudinal Field Multiple Sampling Ionization Chamber for RIBLL2[J]. Nuclear Physics Review, 2012, 29(1): 72-76. doi: 10.11804/NuclPhysRev.29.01.072
Citation: TANG Shu-wen, DUAN Li-min, SUN Zhi-yu, MA Peng, LU Chen-gui, YANG He-run, ZHANG Jin-xia, HU Zheng-guo, XU Hu-shan. A Longitudinal Field Multiple Sampling Ionization Chamber for RIBLL2[J]. Nuclear Physics Review, 2012, 29(1): 72-76. doi: 10.11804/NuclPhysRev.29.01.072

A Longitudinal Field Multiple Sampling Ionization Chamber for RIBLL2

doi: 10.11804/NuclPhysRev.29.01.072
  • Received Date: 1900-01-01
  • Rev Recd Date: 1900-01-01
  • Publish Date: 2012-03-20
  • A longitudinal field MUltiple Sampling Ionization Chamber (MUSIC), which makes multiple measurements of energy loss for very high energy heavy ions at RIBLL2, has been constructed and tested with 3 constituent α source (239Pu: 3.435 MeV, 241Am: 3.913 MeV, 244Cm: 4.356 MeV). The voltage plateau curve has been plotted and -500 V is determined as a proper work voltage. The energy resolution is 271.4 keV FWHM for the sampling unit when 3.435 MeV energy deposited. A Geant4 Monte Carlo simulation is made and it indicates the detector can provide unique particle identification for ions Z≥4.
  • 加载中
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Article Metrics

Article views(2046) PDF downloads(518) Cited by()

Proportional views

A Longitudinal Field Multiple Sampling Ionization Chamber for RIBLL2

doi: 10.11804/NuclPhysRev.29.01.072

Abstract: A longitudinal field MUltiple Sampling Ionization Chamber (MUSIC), which makes multiple measurements of energy loss for very high energy heavy ions at RIBLL2, has been constructed and tested with 3 constituent α source (239Pu: 3.435 MeV, 241Am: 3.913 MeV, 244Cm: 4.356 MeV). The voltage plateau curve has been plotted and -500 V is determined as a proper work voltage. The energy resolution is 271.4 keV FWHM for the sampling unit when 3.435 MeV energy deposited. A Geant4 Monte Carlo simulation is made and it indicates the detector can provide unique particle identification for ions Z≥4.

TANG Shu-wen, DUAN Li-min, SUN Zhi-yu, MA Peng, LU Chen-gui, YANG He-run, ZHANG Jin-xia, HU Zheng-guo, XU Hu-shan. A Longitudinal Field Multiple Sampling Ionization Chamber for RIBLL2[J]. Nuclear Physics Review, 2012, 29(1): 72-76. doi: 10.11804/NuclPhysRev.29.01.072
Citation: TANG Shu-wen, DUAN Li-min, SUN Zhi-yu, MA Peng, LU Chen-gui, YANG He-run, ZHANG Jin-xia, HU Zheng-guo, XU Hu-shan. A Longitudinal Field Multiple Sampling Ionization Chamber for RIBLL2[J]. Nuclear Physics Review, 2012, 29(1): 72-76. doi: 10.11804/NuclPhysRev.29.01.072

Catalog

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return