Advanced Search

LIU Jun-liang, XUE Ying-li, YU De-yang, WU Ye-hong, CHEN Jing, DU Fan, ZHANG Ming-wu, RUAN Fang-fang, WANG Wei, LI Jin-yu, WANG Ping-zhi, KANG Long, CAI Xiao-hong. Guiding of 105 keV Ar7+ Ions through a Gap Formed by a Paired Parallel Glass Plates[J]. Nuclear Physics Review, 2012, 29(4): 425-429. doi: 10.11804/NuclPhysRev.29.04.425
Citation: LIU Jun-liang, XUE Ying-li, YU De-yang, WU Ye-hong, CHEN Jing, DU Fan, ZHANG Ming-wu, RUAN Fang-fang, WANG Wei, LI Jin-yu, WANG Ping-zhi, KANG Long, CAI Xiao-hong. Guiding of 105 keV Ar7+ Ions through a Gap Formed by a Paired Parallel Glass Plates[J]. Nuclear Physics Review, 2012, 29(4): 425-429. doi: 10.11804/NuclPhysRev.29.04.425

Guiding of 105 keV Ar7+ Ions through a Gap Formed by a Paired Parallel Glass Plates

doi: 10.11804/NuclPhysRev.29.04.425
  • Received Date: 1900-01-01
  • Rev Recd Date: 1900-01-01
  • Publish Date: 2012-12-20
  • The transmission of 105 keV Ar7+ ions with high incident current (about 80 nA) through the gap formed by a paired parallel glass plates was investigated. The intensity and angular distribution of the transmitted ions for various tilt angles were measured using a onedimensional position sensitive detector. The results indicate the existence of a guiding effect when Ar7+ ions pass through the gap, but it is different from that for ions passing through nonacapillaries. We found a measurable dependence of the full width at half maximum (FWHM) of the transmitted ions as a function of the tilt angle. In addition, when the gap was tilted with respect to the direction of the incident beam, the observation angle related to the center of the transmitted ions profile was not equal to the tilt angle.
  • 加载中
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Article Metrics

Article views(2402) PDF downloads(516) Cited by()

Proportional views

Guiding of 105 keV Ar7+ Ions through a Gap Formed by a Paired Parallel Glass Plates

doi: 10.11804/NuclPhysRev.29.04.425

Abstract: The transmission of 105 keV Ar7+ ions with high incident current (about 80 nA) through the gap formed by a paired parallel glass plates was investigated. The intensity and angular distribution of the transmitted ions for various tilt angles were measured using a onedimensional position sensitive detector. The results indicate the existence of a guiding effect when Ar7+ ions pass through the gap, but it is different from that for ions passing through nonacapillaries. We found a measurable dependence of the full width at half maximum (FWHM) of the transmitted ions as a function of the tilt angle. In addition, when the gap was tilted with respect to the direction of the incident beam, the observation angle related to the center of the transmitted ions profile was not equal to the tilt angle.

LIU Jun-liang, XUE Ying-li, YU De-yang, WU Ye-hong, CHEN Jing, DU Fan, ZHANG Ming-wu, RUAN Fang-fang, WANG Wei, LI Jin-yu, WANG Ping-zhi, KANG Long, CAI Xiao-hong. Guiding of 105 keV Ar7+ Ions through a Gap Formed by a Paired Parallel Glass Plates[J]. Nuclear Physics Review, 2012, 29(4): 425-429. doi: 10.11804/NuclPhysRev.29.04.425
Citation: LIU Jun-liang, XUE Ying-li, YU De-yang, WU Ye-hong, CHEN Jing, DU Fan, ZHANG Ming-wu, RUAN Fang-fang, WANG Wei, LI Jin-yu, WANG Ping-zhi, KANG Long, CAI Xiao-hong. Guiding of 105 keV Ar7+ Ions through a Gap Formed by a Paired Parallel Glass Plates[J]. Nuclear Physics Review, 2012, 29(4): 425-429. doi: 10.11804/NuclPhysRev.29.04.425

Catalog

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return