Advanced Search

TIAN Li-chao, SUN Zhi-jia, QI Hui-rong, TANG Bin, LÜ Xinyu, CHEN Yuan-bo, OU Yanqun. Digital Readout Method for Position Sensitive Detectors[J]. Nuclear Physics Review, 2013, 30(1): 42-46. doi: 10.11804/NuclPhysRev.30.01.042
Citation: TIAN Li-chao, SUN Zhi-jia, QI Hui-rong, TANG Bin, LÜ Xinyu, CHEN Yuan-bo, OU Yanqun. Digital Readout Method for Position Sensitive Detectors[J]. Nuclear Physics Review, 2013, 30(1): 42-46. doi: 10.11804/NuclPhysRev.30.01.042

Digital Readout Method for Position Sensitive Detectors

doi: 10.11804/NuclPhysRev.30.01.042
  • Received Date: 1900-01-01
  • Rev Recd Date: 1900-01-01
  • Publish Date: 2013-03-20
  • Efficient thermal neutron detectors with large area, two-dimensional position sensitive, high counting rate high detection efficiency and low gamma sensitivity are required to satisfy the demands for the China Spallation Neutron Source (CSNS). Compared with the traditional analog readout method, the digital readout method has the advantages of higher counting rate, smaller quantity of data transmission, simpler readout system and higher signal to noise ratio. The theoretical analysis of the digital readout method is reported in this paper.Used the raw data of GEM detector, the relationship between the position resolution and the width of the readout strip was studied. The results indicate that the digital readout method could be a good choice for the large area position sensitive detector where the requirement of position resolution is less than 4 mm, e.g. the detector of Small-Angle Neutron Scattering (SANS) diffractometer of CSNS.
  • 加载中
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Article Metrics

Article views(2187) PDF downloads(443) Cited by()

Proportional views

Digital Readout Method for Position Sensitive Detectors

doi: 10.11804/NuclPhysRev.30.01.042

Abstract: Efficient thermal neutron detectors with large area, two-dimensional position sensitive, high counting rate high detection efficiency and low gamma sensitivity are required to satisfy the demands for the China Spallation Neutron Source (CSNS). Compared with the traditional analog readout method, the digital readout method has the advantages of higher counting rate, smaller quantity of data transmission, simpler readout system and higher signal to noise ratio. The theoretical analysis of the digital readout method is reported in this paper.Used the raw data of GEM detector, the relationship between the position resolution and the width of the readout strip was studied. The results indicate that the digital readout method could be a good choice for the large area position sensitive detector where the requirement of position resolution is less than 4 mm, e.g. the detector of Small-Angle Neutron Scattering (SANS) diffractometer of CSNS.

TIAN Li-chao, SUN Zhi-jia, QI Hui-rong, TANG Bin, LÜ Xinyu, CHEN Yuan-bo, OU Yanqun. Digital Readout Method for Position Sensitive Detectors[J]. Nuclear Physics Review, 2013, 30(1): 42-46. doi: 10.11804/NuclPhysRev.30.01.042
Citation: TIAN Li-chao, SUN Zhi-jia, QI Hui-rong, TANG Bin, LÜ Xinyu, CHEN Yuan-bo, OU Yanqun. Digital Readout Method for Position Sensitive Detectors[J]. Nuclear Physics Review, 2013, 30(1): 42-46. doi: 10.11804/NuclPhysRev.30.01.042

Catalog

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return