GAO Xingshun, ZHAO Lei, KANG Longfei, LIU Shubin, An Qi. A Multi-channel Scaler Designed for the Experiment of the Reaction Microscope at Lanzhou[J]. Nuclear Physics Review, 2015, 32(1): 73-79. doi: 10.11804/NuclPhysRev.32.01.073
Citation: GAO Xingshun, ZHAO Lei, KANG Longfei, LIU Shubin, An Qi. A Multi-channel Scaler Designed for the Experiment of the Reaction Microscope at Lanzhou[J]. Nuclear Physics Review, 2015, 32(1): 73-79. doi: 10.11804/NuclPhysRev.32.01.073

A Multi-channel Scaler Designed for the Experiment of the Reaction Microscope at Lanzhou

doi: 10.11804/NuclPhysRev.32.01.073
  • Received Date: 1900-01-01
  • Rev Recd Date: 1900-01-01
  • Publish Date: 2015-03-20
  • This article introduces a high resolution and multi-channel scaler based on PXI-3U standard. The maximum repetition frequency of the input signal is 100 MHz, with a counting scale up to 240. This scaler is able to operate in two working modes: counting within a certain time period or between two adjacent input trigger signals. The rst mode is designed for a low counting rate (~ 1 MHz), while the second mode for a high rate ( 100 MHz). Test results indicate that this scaler has a good performance, beyond the application requirement in the experiment of the reaction microscope at Lanzhou (ReMiLa). Besides, with the application of Field Programmable Gate Array (FPGA), this scaler module is exible and convenient to be upgrade in future.
  • 加载中
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Article Metrics

Article views(1376) PDF downloads(527) Cited by()

Proportional views

A Multi-channel Scaler Designed for the Experiment of the Reaction Microscope at Lanzhou

doi: 10.11804/NuclPhysRev.32.01.073

Abstract: This article introduces a high resolution and multi-channel scaler based on PXI-3U standard. The maximum repetition frequency of the input signal is 100 MHz, with a counting scale up to 240. This scaler is able to operate in two working modes: counting within a certain time period or between two adjacent input trigger signals. The rst mode is designed for a low counting rate (~ 1 MHz), while the second mode for a high rate ( 100 MHz). Test results indicate that this scaler has a good performance, beyond the application requirement in the experiment of the reaction microscope at Lanzhou (ReMiLa). Besides, with the application of Field Programmable Gate Array (FPGA), this scaler module is exible and convenient to be upgrade in future.

GAO Xingshun, ZHAO Lei, KANG Longfei, LIU Shubin, An Qi. A Multi-channel Scaler Designed for the Experiment of the Reaction Microscope at Lanzhou[J]. Nuclear Physics Review, 2015, 32(1): 73-79. doi: 10.11804/NuclPhysRev.32.01.073
Citation: GAO Xingshun, ZHAO Lei, KANG Longfei, LIU Shubin, An Qi. A Multi-channel Scaler Designed for the Experiment of the Reaction Microscope at Lanzhou[J]. Nuclear Physics Review, 2015, 32(1): 73-79. doi: 10.11804/NuclPhysRev.32.01.073