JIN Peng, WANG Xianwu, TIAN Ruixia, XU Zhe, FENG Yong, LAN Tao. Dee Voltage Calibration of 31.02 MHz Cyclotron Resonance Cavity[J]. Nuclear Physics Review, 2015, 32(3): 301-305. doi: 10.11804/NuclPhysRev.32.03.301
Citation: JIN Peng, WANG Xianwu, TIAN Ruixia, XU Zhe, FENG Yong, LAN Tao. Dee Voltage Calibration of 31.02 MHz Cyclotron Resonance Cavity[J]. Nuclear Physics Review, 2015, 32(3): 301-305. doi: 10.11804/NuclPhysRev.32.03.301

Dee Voltage Calibration of 31.02 MHz Cyclotron Resonance Cavity

doi: 10.11804/NuclPhysRev.32.03.301
  • Received Date: 1900-01-01
  • Rev Recd Date: 1900-01-01
  • Publish Date: 2015-09-20
  • The 31.02 MHz cyclotron RF system of Heavy Ion Medical Machine (HIMM) in IMP(Institute of Modern Physics, Chinese Academy of Sciences) has completed the design and commssioning,and now has already been put into operation. Its peak voltage requires 70 kV, but the precise calculation of the Dee voltage is still a difficulty problem, we can get the value Rp/Q0 of the cavity by CST simulation, and then combining the actual input power for cavity to calculate the real Dee voltage. In order to verify its accuracy, we use the bremsstrahlung method to test the cavity voltage under the condition of same input power. The error between test results and calculation is less than 0.6%.
  • 加载中
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Article Metrics

Article views(1073) PDF downloads(287) Cited by()

Proportional views

Dee Voltage Calibration of 31.02 MHz Cyclotron Resonance Cavity

doi: 10.11804/NuclPhysRev.32.03.301

Abstract: The 31.02 MHz cyclotron RF system of Heavy Ion Medical Machine (HIMM) in IMP(Institute of Modern Physics, Chinese Academy of Sciences) has completed the design and commssioning,and now has already been put into operation. Its peak voltage requires 70 kV, but the precise calculation of the Dee voltage is still a difficulty problem, we can get the value Rp/Q0 of the cavity by CST simulation, and then combining the actual input power for cavity to calculate the real Dee voltage. In order to verify its accuracy, we use the bremsstrahlung method to test the cavity voltage under the condition of same input power. The error between test results and calculation is less than 0.6%.

JIN Peng, WANG Xianwu, TIAN Ruixia, XU Zhe, FENG Yong, LAN Tao. Dee Voltage Calibration of 31.02 MHz Cyclotron Resonance Cavity[J]. Nuclear Physics Review, 2015, 32(3): 301-305. doi: 10.11804/NuclPhysRev.32.03.301
Citation: JIN Peng, WANG Xianwu, TIAN Ruixia, XU Zhe, FENG Yong, LAN Tao. Dee Voltage Calibration of 31.02 MHz Cyclotron Resonance Cavity[J]. Nuclear Physics Review, 2015, 32(3): 301-305. doi: 10.11804/NuclPhysRev.32.03.301