Investigation of HV Power Supply for GEM Detector in High Dose Rate

doi: 10.11804/NuclPhysRev.32.03.335
  • Received Date: 1900-01-01
  • Rev Recd Date: 1900-01-01
  • Publish Date: 2015-09-20
  • There are two methods of the HV power supply for the GEM detector. One is a HV channel divided by the resistive chain and the other is the several separate HV channels. In the smaller dose rate of X-ray, all of the methods are similar. When the dose rate increases, the resistive chain-dividing mode has more obvious saturation effect and the working voltage of the GEM detector is unstable. In the paper, a GEM detector with an effective area of 100 mm100 mm has been studied in the high dose rate using X-tube. The unit values in the divider resistance chain are set to 1, 2, 5 and 30 MΩ respectively in the test. With the resistive chain-dividing mode, the readout current of the GEM detector’s anode tends to saturate when the dose rate of X-ray increases,and the reasons of the saturation effect are analyzed. The results indicate that the effective absorbed dose of X-ray by the triple GEMs detector reaches to the pecific value and the divider resistance needs to re-select, even the several separate HV channels mode should be considered. It will keep the constant of the working voltage of the GEM detector without the saturation effect and gain variation and the performance of GEM detector is stable.
  • 加载中
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Article Metrics

Article views(1408) PDF downloads(262) Cited by()

Proportional views

Investigation of HV Power Supply for GEM Detector in High Dose Rate

doi: 10.11804/NuclPhysRev.32.03.335

Abstract: There are two methods of the HV power supply for the GEM detector. One is a HV channel divided by the resistive chain and the other is the several separate HV channels. In the smaller dose rate of X-ray, all of the methods are similar. When the dose rate increases, the resistive chain-dividing mode has more obvious saturation effect and the working voltage of the GEM detector is unstable. In the paper, a GEM detector with an effective area of 100 mm100 mm has been studied in the high dose rate using X-tube. The unit values in the divider resistance chain are set to 1, 2, 5 and 30 MΩ respectively in the test. With the resistive chain-dividing mode, the readout current of the GEM detector’s anode tends to saturate when the dose rate of X-ray increases,and the reasons of the saturation effect are analyzed. The results indicate that the effective absorbed dose of X-ray by the triple GEMs detector reaches to the pecific value and the divider resistance needs to re-select, even the several separate HV channels mode should be considered. It will keep the constant of the working voltage of the GEM detector without the saturation effect and gain variation and the performance of GEM detector is stable.

WEI Kun, QI Huirong, ZHANG Yulian, WEN Zhiwen, ZHANG Jian, OUYANG Qun, . Investigation of HV Power Supply for GEM Detector in High Dose Rate[J]. Nuclear Physics Review, 2015, 32(3): 335-340. doi: 10.11804/NuclPhysRev.32.03.335
Citation: WEI Kun, QI Huirong, ZHANG Yulian, WEN Zhiwen, ZHANG Jian, OUYANG Qun, . Investigation of HV Power Supply for GEM Detector in High Dose Rate[J]. Nuclear Physics Review, 2015, 32(3): 335-340. doi: 10.11804/NuclPhysRev.32.03.335

Catalog

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return