SU Xiaobin, LIU Yang, HOU Long, WANG Zhaohui, WANG Qi. Efficiency Calibration Method of NaI Detector in 23.8 MeV for γ-Ray[J]. Nuclear Physics Review, 2015, 32(4): 440-445. doi: 10.11804/NuclPhysRev.32.04.440
Citation: SU Xiaobin, LIU Yang, HOU Long, WANG Zhaohui, WANG Qi. Efficiency Calibration Method of NaI Detector in 23.8 MeV for γ-Ray[J]. Nuclear Physics Review, 2015, 32(4): 440-445. doi: 10.11804/NuclPhysRev.32.04.440

Efficiency Calibration Method of NaI Detector in 23.8 MeV for γ-Ray

doi: 10.11804/NuclPhysRev.32.04.440
  • Received Date: 2015-01-28
  • Accepted Date: 2015-12-20
  • Rev Recd Date: 2015-04-14
  • Publish Date: 2015-12-20
  • In the study of D(d,γ)4He radiative capture reactions research, which is very important for fusion and astrophysics, the efficiency calibration of the detector is necessary. Due to the restriction on energy of the standard gamma source, the efficiency calibration of high-energy gamma-rays can not be calibrated by a standard source. In this paper, the method combining the experimental measurements and calculations for the efficiency calibrations of high energy gamma rays is given in the experiment of 6.13MeV gamma rays efficiency calibration using NaI detector, the efficiency curve of which is calculated by MCNP-4C and corrected experimentally. In this case, the detection efficiency of 23.8MeV gamma ray is known. The method provides a reference to high energy gamma ray efficiency calibration.
  • 加载中
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Article Metrics

Article views(1611) PDF downloads(233) Cited by()

Proportional views

Efficiency Calibration Method of NaI Detector in 23.8 MeV for γ-Ray

doi: 10.11804/NuclPhysRev.32.04.440

Abstract: In the study of D(d,γ)4He radiative capture reactions research, which is very important for fusion and astrophysics, the efficiency calibration of the detector is necessary. Due to the restriction on energy of the standard gamma source, the efficiency calibration of high-energy gamma-rays can not be calibrated by a standard source. In this paper, the method combining the experimental measurements and calculations for the efficiency calibrations of high energy gamma rays is given in the experiment of 6.13MeV gamma rays efficiency calibration using NaI detector, the efficiency curve of which is calculated by MCNP-4C and corrected experimentally. In this case, the detection efficiency of 23.8MeV gamma ray is known. The method provides a reference to high energy gamma ray efficiency calibration.

SU Xiaobin, LIU Yang, HOU Long, WANG Zhaohui, WANG Qi. Efficiency Calibration Method of NaI Detector in 23.8 MeV for γ-Ray[J]. Nuclear Physics Review, 2015, 32(4): 440-445. doi: 10.11804/NuclPhysRev.32.04.440
Citation: SU Xiaobin, LIU Yang, HOU Long, WANG Zhaohui, WANG Qi. Efficiency Calibration Method of NaI Detector in 23.8 MeV for γ-Ray[J]. Nuclear Physics Review, 2015, 32(4): 440-445. doi: 10.11804/NuclPhysRev.32.04.440

Catalog

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return