Diagnostics and Measurements of 7Li Ion Beam on the New Terminal at HI-13 Tandem Accelerator for Radiobiological Application[J]. Nuclear Physics Review, 2015, 32(4): 467-472. doi: 10.11804/NuclPhysRev.32.04.467
Citation: Diagnostics and Measurements of 7Li Ion Beam on the New Terminal at HI-13 Tandem Accelerator for Radiobiological Application[J]. Nuclear Physics Review, 2015, 32(4): 467-472. doi: 10.11804/NuclPhysRev.32.04.467

Diagnostics and Measurements of 7Li Ion Beam on the New Terminal at HI-13 Tandem Accelerator for Radiobiological Application

doi: 10.11804/NuclPhysRev.32.04.467
  • Received Date: 2015-03-06
  • Accepted Date: 2015-12-20
  • Rev Recd Date: 2015-05-07
  • Publish Date: 2015-12-20
  • 7Li ion with high linear energy transfer (LET) radiation has been used in radiobiological research, takes main effect in Boron Neutron Capture Therapy and is applied in radiation mutagenic breeding. This experiment was carried on the new terminal established for radiobiological application, located at the end of R20 branch beam line of HI-13 tandem accelerator. The beam qualities of 7Li ions of 43MeV generated by HI-13 tandem accelerator, including spot size and uniformity and particle fluence accuracy were measured using different detection methods. The results showed that beam uniformity was over 90% at 5cm×5cm area, the flux of S1 and M3 had a good linear relationship as particle flux ranged from 4.2×104 particles/cm2/s to 1.5×105 particles/cm2/s, and particle fluence accuracy was better than 90%. All the results showed that the beam qualities of 7Li ions finely met the basic requirements for radiation biological experiment. It provides important method to study biological effects for fundamental research and tumor therapy or radiation mutagenic breeding application associated with 7Li ions.
  • 加载中
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Article Metrics

Article views(1203) PDF downloads(245) Cited by()

Proportional views

Diagnostics and Measurements of 7Li Ion Beam on the New Terminal at HI-13 Tandem Accelerator for Radiobiological Application

doi: 10.11804/NuclPhysRev.32.04.467

Abstract: 7Li ion with high linear energy transfer (LET) radiation has been used in radiobiological research, takes main effect in Boron Neutron Capture Therapy and is applied in radiation mutagenic breeding. This experiment was carried on the new terminal established for radiobiological application, located at the end of R20 branch beam line of HI-13 tandem accelerator. The beam qualities of 7Li ions of 43MeV generated by HI-13 tandem accelerator, including spot size and uniformity and particle fluence accuracy were measured using different detection methods. The results showed that beam uniformity was over 90% at 5cm×5cm area, the flux of S1 and M3 had a good linear relationship as particle flux ranged from 4.2×104 particles/cm2/s to 1.5×105 particles/cm2/s, and particle fluence accuracy was better than 90%. All the results showed that the beam qualities of 7Li ions finely met the basic requirements for radiation biological experiment. It provides important method to study biological effects for fundamental research and tumor therapy or radiation mutagenic breeding application associated with 7Li ions.

Diagnostics and Measurements of 7Li Ion Beam on the New Terminal at HI-13 Tandem Accelerator for Radiobiological Application[J]. Nuclear Physics Review, 2015, 32(4): 467-472. doi: 10.11804/NuclPhysRev.32.04.467
Citation: Diagnostics and Measurements of 7Li Ion Beam on the New Terminal at HI-13 Tandem Accelerator for Radiobiological Application[J]. Nuclear Physics Review, 2015, 32(4): 467-472. doi: 10.11804/NuclPhysRev.32.04.467

Catalog

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return