ZHANG Xing, HU Rongjiang, LU Chengui, YANG Herun, MA Peng, GUAN Yuanfan, WEI Xianglun, DUAN Limin, WANG Jiansong, ZHENG Yong, . Study of Double-Layer Multi-Wire Proportional Chamber based on LC Delay Circuit[J]. Nuclear Physics Review, 2017, 34(3): 591-597. doi: 10.11804/NuclPhysRev.34.03.591
Citation: ZHANG Xing, HU Rongjiang, LU Chengui, YANG Herun, MA Peng, GUAN Yuanfan, WEI Xianglun, DUAN Limin, WANG Jiansong, ZHENG Yong, . Study of Double-Layer Multi-Wire Proportional Chamber based on LC Delay Circuit[J]. Nuclear Physics Review, 2017, 34(3): 591-597. doi: 10.11804/NuclPhysRev.34.03.591

Study of Double-Layer Multi-Wire Proportional Chamber based on LC Delay Circuit

doi: 10.11804/NuclPhysRev.34.03.591
Funds:  National Natural Science Foundation of China (11375246, 11405223, 11375238); National Basic Research Program of China (973 Program) (2014CB845405)
More Information
  • Corresponding author: 10.11804/NuclPhysRev.34.03.591
  • Received Date: 2016-12-08
  • Rev Recd Date: 2017-04-23
  • Publish Date: 2017-07-18
  • A double-layer Multi-Wire Proportional Chamber (MWPC) with 100 mm×80 mm active area has been developed for Radioactive Ion Beam Line in Lanzhou(RIBLL Ⅱ). The position information has been obtained by a LC delay circuit readout method. Being called of double-layer MWPC, it is composed of two full MWPCs, each consists of an anode plane sandwiched between two parallel cathode planes, anode wires and cathode wires are perpendicular to each other. In order to improve the detection efficiency, the cathode wires of corresponding position are combined to enhance inductive signal. The cathode wires of two full MWPCs are orthogonally placed to give two coordinates of the incident particles. The sensitivity uniformity is also found to be relatively good and the position resolution of X, Y direction are measured to be 199.9 and 154.0 μm using a 55Fe-5.9 keV X ray, respectively. The position linearity of X, Y direction are as good as 0.999 for whole sensitive area of the detector. The detector has been used successfully on the experiment at RIBLL Ⅱ.
  • [1] CHARPAK G, BOUCLIER R, BRESSANI T, et al. Nucl Instr Meth, 1968, 62:262.
    [2] BRESKIN A. Nucl Instr Meth, 1982, 196:11.
    [3] TANG Shuwen, XU Hushan, MA Peng, et al. Chinese Physics C, 2013, 37(6):066002.
    [4] ZHANG Junwei, LU Chengui, DUAN Limin, et al. Chinese Physics C, 2014, 38(2):026004.
    [5] MORRIS C L, BOWLES T J, GONZALES J, et al. Nucl Instr Meth A, 2009, 599:248.
    [6] HAN Liying, LI Qite, FAISAL Q, et al. Chinese Physics C, 2009, 33(5):364.
    [7] KUMAGAI H, OHNISHI T, FUKUDA N, et al. Nucl Instr Meth B, 2013, 317:717.
    [8] Kumagai H, Ozawa A, Fukuda N, et al. Nucl Instr Meth A, 2001, 470:562.
    [9] Available on the web http://phillipsscientific.com/pdf/7186ds.pdf
    [10] Available on the web http://www.datadelay.com
    [11] ZHOU Yi, LI Cheng, SUN Yongjie. Nucl Instr Meth A, 2009, 604:71.
    [12] GUEDES G P, BRESKIN A, CHECHIK R. Nucl Instr Meth A, 2003, 513:473.
    [13] Available on the web http://uk.rs-online.com/web/p/wirewound-surface-mount-inductors/4811911P/
    [14] Available on the web http://au.rs-online.com/web/p/ceramicmultilayer-capacitors/7235903P/
    [15] SMITH G C, YU B. IEEE Trans on Nucl Sci, 1995, 42(4):541.
    [16] CHARPAK G, SAULI F. Nucl Instr Meth, 1979, 162:405.
  • 加载中
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Article Metrics

Article views(1460) PDF downloads(217) Cited by()

Proportional views

Study of Double-Layer Multi-Wire Proportional Chamber based on LC Delay Circuit

doi: 10.11804/NuclPhysRev.34.03.591
Funds:  National Natural Science Foundation of China (11375246, 11405223, 11375238); National Basic Research Program of China (973 Program) (2014CB845405)
    Corresponding author: 10.11804/NuclPhysRev.34.03.591

Abstract: A double-layer Multi-Wire Proportional Chamber (MWPC) with 100 mm×80 mm active area has been developed for Radioactive Ion Beam Line in Lanzhou(RIBLL Ⅱ). The position information has been obtained by a LC delay circuit readout method. Being called of double-layer MWPC, it is composed of two full MWPCs, each consists of an anode plane sandwiched between two parallel cathode planes, anode wires and cathode wires are perpendicular to each other. In order to improve the detection efficiency, the cathode wires of corresponding position are combined to enhance inductive signal. The cathode wires of two full MWPCs are orthogonally placed to give two coordinates of the incident particles. The sensitivity uniformity is also found to be relatively good and the position resolution of X, Y direction are measured to be 199.9 and 154.0 μm using a 55Fe-5.9 keV X ray, respectively. The position linearity of X, Y direction are as good as 0.999 for whole sensitive area of the detector. The detector has been used successfully on the experiment at RIBLL Ⅱ.

ZHANG Xing, HU Rongjiang, LU Chengui, YANG Herun, MA Peng, GUAN Yuanfan, WEI Xianglun, DUAN Limin, WANG Jiansong, ZHENG Yong, . Study of Double-Layer Multi-Wire Proportional Chamber based on LC Delay Circuit[J]. Nuclear Physics Review, 2017, 34(3): 591-597. doi: 10.11804/NuclPhysRev.34.03.591
Citation: ZHANG Xing, HU Rongjiang, LU Chengui, YANG Herun, MA Peng, GUAN Yuanfan, WEI Xianglun, DUAN Limin, WANG Jiansong, ZHENG Yong, . Study of Double-Layer Multi-Wire Proportional Chamber based on LC Delay Circuit[J]. Nuclear Physics Review, 2017, 34(3): 591-597. doi: 10.11804/NuclPhysRev.34.03.591