ZHOU Yuanjie, MA Peng, WANG Jiansong, DUAN Limin, YANG Herun, HU Rongjiang, LU Chengui, ZHANG Junwei, XIAO Zhigang, WANG Rensheng, ZHANG Yan, HUANG Yan, LÜ Limin, CHEN Wenjing, YI Han. A Large Position-sensitive PPAC[J]. Nuclear Physics Review, 2017, 34(4): 768-772. doi: 10.11804/NuclPhysRev.34.04.768
Citation:
|
ZHOU Yuanjie, MA Peng, WANG Jiansong, DUAN Limin, YANG Herun, HU Rongjiang, LU Chengui, ZHANG Junwei, XIAO Zhigang, WANG Rensheng, ZHANG Yan, HUANG Yan, LÜ Limin, CHEN Wenjing, YI Han. A Large Position-sensitive PPAC[J]. Nuclear Physics Review, 2017, 34(4): 768-772. doi: 10.11804/NuclPhysRev.34.04.768
|
A Large Position-sensitive PPAC
-
ZHOU Yuanjie1,2
,
-
MA Peng1,2
,
,
-
WANG Jiansong2
,
-
DUAN Limin2
,
-
YANG Herun2
,
-
HU Rongjiang2
,
-
LU Chengui2
,
-
ZHANG Junwei1,2
,
-
XIAO Zhigang3
,
-
WANG Rensheng3
,
-
ZHANG Yan3
,
-
HUANG Yan3
,
-
LÜ Limin3
,
-
CHEN Wenjing3
,
-
YI Han3
- 1.
University of Chinese Science Academy, Beijing 100049, China;
- 2.
Institute of Modern Physics, Chinese Academy of Sciences, Lanzhou 730000, China;
- 3.
Department of Physics, Tsinghua University, Beijing 100084 China
Funds:
National Basic Research Program of China(973 Program)(2014CB845405);National Natural Science Foundation of China(11205221, 11205209, 11305232, 11375246)
- Received Date: 2017-02-16
- Rev Recd Date:
2017-11-24
- Publish Date:
2017-12-20
-
Abstract
A kind of large position sensitive parallel plate avalanche counter(PPAC) was developed at Gas Detector Research Group, Institute of Modern Physics of CAS. Each of the detector with large sensitive area of 244 mm×284 mm, consists of one central cathode, X anode and Y anode. The cathode plane in the middle of detector is a 1.5 μm thick Mylar foil coated with a thin Au-layer on both sides. The position resolution of the PPAC is better than 4 mm, and the time resolution is 0.42 ns. The detectors were used in the fission experiment with 30MeV/u 40Ar beam bombarding on a gold target to measure the velocity of the fission fragments at Radioactive Ion Beam Line In Lanzhou(RIBLL). Four PPACs were used and the experiment result showed that a rather high detection efficiency (90.3%) is achieved. The position distribution of fission fragments is given by PPACs, which provides very good experimental data for further theoretical analysis.
-
References
[1]
|
KEUFFEL J W. 1949, Rev Sci, 1949, 20:202. |
[2]
|
PIDD R W, MANDANSKY L. Phys Rev, 1949, 75:627. |
[3]
|
HEMPEL G, HOPKINS F, SCHATZ G. Nucl Instr Meth A, 1975, 131:4450. |
[4]
|
KUMAGAI H, OZAWA A. Nucl Instr Meth A,2001, 470:562. |
[5]
|
FREEMAN C G, HERRICK D M, BRYAN D C, et al. Nucl Instr Meth A, 1994, 357:450. |
[6]
|
BHATTACHARYA P, BASU P, CHATTERJEE M I. Nucl Instr Meth A, 1989, 276:583. |
[7]
|
KUMAGAI H, OZAWA A, FUKUDA N, et al. Nucl Instr Meth A, 2001, 470:562. |
[8]
|
HUA Hui, JIANG Dongxing, LI Xiangqing, et al. Nucl Instr Meth A, 2002, 481:160. |
[9]
|
FANO U. Ann Rep Nucl Sci, 1963, 13:1. |
[10]
|
ZHANG Yan, TIAN Junlong, CHENG Wenjing, et al. Phys Rev C, 2017, 95:041602. |
-
-
Proportional views
-