Advanced Search
Volume 36 Issue 2
Jul.  2019
Turn off MathJax
Article Contents

PAN Xiaodong, ZHANG Cui, SHANG Hongjie, QI Ji, LI Gongping. Study on the Factors Influencing the Quality of Cone-beam Computed Tomography[J]. Nuclear Physics Review, 2019, 36(2): 211-217. doi: 10.11804/NuclPhysRev.36.02.211
Citation: PAN Xiaodong, ZHANG Cui, SHANG Hongjie, QI Ji, LI Gongping. Study on the Factors Influencing the Quality of Cone-beam Computed Tomography[J]. Nuclear Physics Review, 2019, 36(2): 211-217. doi: 10.11804/NuclPhysRev.36.02.211

Study on the Factors Influencing the Quality of Cone-beam Computed Tomography

doi: 10.11804/NuclPhysRev.36.02.211
Funds:  Fundamental Research Funds for Central Universities of Ministry of Education of China (lzujbky2016-208, lzujbky-2016-32).
  • Received Date: 2018-09-15
  • Rev Recd Date: 2019-04-23
  • Publish Date: 2019-06-20
  • The imaging quality of the CT system is influenced by many factors. It is necessary to study the influence caused by each factor in order to get a better imaging result. Based on a cone-beam CT system developed by our group, and under the near detector condition, using a standard workpiece of aluminum to study the influences on the imaging quality of CT system, produced by the factors of projection acquisition range and step, tube voltage and current, focal spot size, object position on turntable, beam-hardening correction and image optimizing. The results show that the influence of projection acquisition range on imaging quality is very small, and the smaller acquisition step can improve imaging quality; appropriately increasing the tube voltage can reduce the beam-hardening artifacts and enlarging the tube current can reduce image noise; the smaller focal spot size can enhance the spatial resolution of the image, but was not obvious under the near detector geometry; sample position on turntable does not affect the reconstruction result; hardening correction can greatly eliminate beam-hardening artifacts. Finally, image optimizing can improve image quality effectively. This work provides a reference for the development and application of the CT system.
  • [1] BABA R, UEDA K, OKABE M. Dentmaxillofacial Radiology, 2004, 33(33):285.
    [2] KASTNER J, HARRER B, REQUENA G, et al. Ndt & E International Independent Nondestructive Testing & Evaluation, 2010, 43(7):599.
    [3] AGRAWAL A K, SARKAR P S, KASHYAP Y S, et al. Journal of Nondestructive Evaluation, 2016, 35(3):1.
    [4] GROH B A, SIEWERDSEN J H, DRAKE D G, et al. Medical Physics, 2002, 29(6):967.
    [5] BAKER D R, MANCINI L, POLACCI M, et al. Lithos, 2012, 148(9):262.
    [6] MICELI A, THIERRY R, FLISCH A, et al. Nucl Instr and Meth A, 2007, 583(2-3):313.
    [7] ZHANG H, HUANG K D, SHI Y K, et al. Chinese Physics C, 2015, 39(3):101.
    [8] WANG Xiangang, YE Qing, GUO Zhiping, et al. CT Theory and Applications, 2009, 18(4):26. (in Chinese) (王贤刚, 叶青, 郭志平, 等. CT理论与应用研究, 2009, 18(4):26.)
    [9] WANG Jue, TAN Hui, HUANG Liang, et al. Chinese Journal of Scientific and Instrument, 2009, 30(4):722. (in Chinese) (王珏, 谭辉, 黄亮, 等. 仪器仪表学报, 2009, 30(4):722.)
    [10] YESTER M V, BARNES G T. Geometrical Limitations of Computed Tomography (CT) Scanner Resolution[C]//Application of Optical Instrumentation in Medicine VI. International Society for Optics and Photonics, 1977, 127:296.
    [11] ZHANG Cui, LI Gongping, PAN Xiaodong, et al. Nuclear Techniques, 2015, 38(9):8. (in Chinese) (张催, 李公平, 潘小东, 等. 核技术, 2015, 38(9):8.)
    [12] TURBELL H. Cone-beam reconstruction using filtered backprojection[D]. Linköping:Linköping University Electronic Press, 2001:19.
    [13] ZHANG Cui, ZHANG Yihai, SHANG Hongjie, et al. Atomic Energy Science and Technology, 2016, 50(10):1859. (in Chinese) (张催, 张益海, 商宏杰, 等. 原子能科学技术, 2016, 50(10):1859.)
    [14] ZHANG Yihai, ZHANG Cui, PAN Xiaodong, et al. Nondestructive Testing, 2017, 39(6):8. (in Chinese) (张益海, 张催, 潘小东, 等. 无损检测, 2017, 39(6):8.)
  • 加载中
通讯作者: 陈斌, bchen63@163.com
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Article Metrics

Article views(1291) PDF downloads(63) Cited by()

Proportional views

Study on the Factors Influencing the Quality of Cone-beam Computed Tomography

doi: 10.11804/NuclPhysRev.36.02.211
Funds:  Fundamental Research Funds for Central Universities of Ministry of Education of China (lzujbky2016-208, lzujbky-2016-32).

Abstract: The imaging quality of the CT system is influenced by many factors. It is necessary to study the influence caused by each factor in order to get a better imaging result. Based on a cone-beam CT system developed by our group, and under the near detector condition, using a standard workpiece of aluminum to study the influences on the imaging quality of CT system, produced by the factors of projection acquisition range and step, tube voltage and current, focal spot size, object position on turntable, beam-hardening correction and image optimizing. The results show that the influence of projection acquisition range on imaging quality is very small, and the smaller acquisition step can improve imaging quality; appropriately increasing the tube voltage can reduce the beam-hardening artifacts and enlarging the tube current can reduce image noise; the smaller focal spot size can enhance the spatial resolution of the image, but was not obvious under the near detector geometry; sample position on turntable does not affect the reconstruction result; hardening correction can greatly eliminate beam-hardening artifacts. Finally, image optimizing can improve image quality effectively. This work provides a reference for the development and application of the CT system.

PAN Xiaodong, ZHANG Cui, SHANG Hongjie, QI Ji, LI Gongping. Study on the Factors Influencing the Quality of Cone-beam Computed Tomography[J]. Nuclear Physics Review, 2019, 36(2): 211-217. doi: 10.11804/NuclPhysRev.36.02.211
Citation: PAN Xiaodong, ZHANG Cui, SHANG Hongjie, QI Ji, LI Gongping. Study on the Factors Influencing the Quality of Cone-beam Computed Tomography[J]. Nuclear Physics Review, 2019, 36(2): 211-217. doi: 10.11804/NuclPhysRev.36.02.211
Reference (14)

Catalog

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return