LI Weilong, LI Shengpeng, LI Min. Design and Development of Motion Control System for Heavy Ion Medical Machine Beam Diagnostics Detector[J]. Nuclear Physics Review, 2019, 36(4): 433-440. doi: 10.11804/NuclPhysRev.36.04.433
Citation:
|
LI Weilong, LI Shengpeng, LI Min. Design and Development of Motion Control System for Heavy Ion Medical Machine Beam Diagnostics Detector[J]. Nuclear Physics Review, 2019, 36(4): 433-440. doi: 10.11804/NuclPhysRev.36.04.433
|
Design and Development of Motion Control System for Heavy Ion Medical Machine Beam Diagnostics Detector
- 1.
University of Chinese Academy of Sciences, Beijing 100049, China;
- 2.
Institute of Modern Physics, Chinese Academy of Sciences, Lanzhou 730000, China;
- 3.
LanZhou KeJin TaiJi Corporation, LTD, Lanzhou 730000, China
- Received Date: 2019-06-03
- Rev Recd Date:
2019-07-05
- Publish Date:
2019-12-20
-
Abstract
It is necessary to measure beam parameters with beam diagnostics detectors for HIMM(Heavy Ion Medical Machine), most of which are interceptive detectors that will be inserted into the center of the beam pipeline while measuring the beam parameters and be pulled out when the measurement is finished. Furthermore, some of the detectors need to be controlled harmonically. In this paper, the architecture of the motion control system is designed and implemented based on the EtherCAT protocol. The client-server software system based on OPC UA protocol is developed and tested with beam. The motion control system of all beam diagnostics detectors has passed the verification of the CFDA(China-Food and Drug Administration) and been running since 2017 with beam. The results show that the system is of high stability and transplantability characters, the control accuracy and control mode can fully meet the application requirements.
-
References
[1]
|
SONG Mingtao, ZHAN Wenlong, WEI Baowen, et al. Nuclear Physics Review, 2001, 18(2):116.(in Chinese)(宋明涛,詹文龙,魏宝文,等.原子核物理评论, 2007, 18(2):116.) |
[2]
|
XIAO Guoqing, ZHANG Hong, LI Qiang, et al. Nuclear Physics Review, 2007, 24(2):85.(in Chinese)(肖国青,张红,李强,等.原子核物理评论, 2007, 24(2):85.) |
[3]
|
CERFF K, HAAS D, JAKEL D. et al. Setup and Diagnostics of Motion Control at Anka Beam Lines[C]//Proceedings of PCaPAC2014, Karlsruhe, Germany, 2014:198. |
[4]
|
WITTENBURG K. Beam Size Measurements Using Wire Scanners[C]//Topical Workshop on Emittance Measurements for Light Sources and FELs, Barcelona, Spain, January 29-30, 2018. |
[5]
|
LI Min. The Design and Implementation of Front-end Control System of Beam Diagnostics for Heavy-ion Accelerator[D]. Lanzhou:Graduate University of the Chinese Academy of Sciences (IMP)2015:91.(in Chinese)(李敏. HIMM束流诊断前端控制系统的设计与实现[D].兰州:中国科学院研究生院(近代物理研究所)2015:91.) |
[6]
|
BeckHoff. Embedded PC CX[EB/OL].[2019-05-15]. http://www.beckhoff.com.cn/. 37(12):. |
[7]
|
MIN Xiaoshuang, YANG Xin. Information technology and Network security, 2018, 37(12):71.(in Chinese)(闵晓霜,杨鑫.信息技术与网络安全, 2018, 37(12):71.) |
-
-
Proportional views
-